The handrail must be at a consistent height with the top of the gripping surface between 34 to 38 inches above the walking surface, stair, or ramp. In our experience, regulators recommend splitting the difference (36 inches) if there is any confusion about the proper height.

How must staircase handrails be constructed to be ADA compliant?

A railing must be located on both sides of the stairway, ramp, etc. No matter which side of a stairway or ramp a person chooses to use, they should have the support of an ADA compliant handrail. There must also be at least 36 inches of space between the two railings to allow wheelchairs and people to pass through.

Does ADA require handrails on both sides of stairs?

Handrails are required on both sides of stairs and ramps. They are placed between 34 inches and 38 inches above the leading edge of a stair tread, the ramp surface, or the walking surface. Where children are the primary users of a facility, the ADA recommends a second handrail for children.

What is the maximum diameter of a ADA compliant handrail?

Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum.

Are handrails a legal requirement?

Handrails are mandatory. Stairs should have a handrail on at least one side if they are less than one metre wide, and on both sides if wider than this.

What is the standard for handrails?

You should fit a handrail at a height between 900mm and 1000mm from the pitch line of the stairs, or the floor for landings. This is approximately 35.4–39 inches. Staircases require at least one handrail: If the stairs are less than 1m wide: provide a handrail on one or both sides.

How high should a handrail be?

U.S. codes require railings against a wall to be between 30 inches and 38 inches high, while handrails on open stairs must be 34 to 38 inches high.

What is max slope for ADA ramps?

the U.S. per the US ADA (Americans with Disabilities Act), a ramp is a sloping route constructed with a slope greater than 1:20 (one inch of vertical rise for every 20 inches of horizontal length, or run) and must conform to the standard ADA specifications for ramps. Ramps may have a maximum slope of 1:12.

Is there a maximum length an ADA ramp can be?

Is there a maximum length an ADA ramp can be? ANSWER: There is no maximum length a compliant accessible ramp can be. However, a ramp is limited to a 30″ maximum rise and then a level landing must be provided before the rise continues. A ramp can slope no more than 1:12 (8.3%) and if the rise is 1:20 (5%) or less it is not considered a ramp.

What is the maximum distance between handrails?

What is the maximum distance between handrails? 30 inches of a handrail. Other than OSHA, all other codes and standards require that handrails be placed between 34 and 38 inches above the ramp, walking surface, or nosing. recommends a maximum height of 28 inches with a minimum of 9 inches of clearance between the child’s rail and the adult rail.