How much do precast lintels weigh?

How much do precast lintels weigh?

Lintels are lightweight concrete: unit weight 100 pcf, compressive strength 3,000 psi or normal weight concrete: unit weight 126 pcf, compressive strength 3,000 psi.

What is the weight of a lintel?

Quality Control

Weight Weight
Length 108 x 70mm 145 x 70mm
0.9 m 16.4 20.5
1.2 m 21.8 27.3
1.5 m 27.3 34.1

How heavy is a 8ft concrete lintel?

56 pounds per foot
For setting purposes, the 4 x 8 concrete lintel weighs approximately 27 pounds per lineal foot and the 8 x 8 lintel weighs 56 pounds per foot.

How is self weight lintel calculated?

2. Determination of Loads and Moments on RCC Lintel Beam

  1. Self-weight of the lintel per metre length (kN/m) w = ( 1 x b x D ) x Density of RCC.
  2. Moment due to self-weight of Lintel, M1 = wl2/8.
  3. Moment due to triangular load of masonry wall above the lintel, M2 = Wl/6.
  4. Total Bending Moment M = M1 + M2

How thick is a concrete lintel?

Box lintels are used for solid wall construction, with the 100mm ranges used for single skin internal walls and the 200mm ranges used for double skins, typically external walls, with no cavity.

How thick should a lintel be?

What’s the biggest concrete lintel?

Concrete lintels are available in a range of lengths including: 600mm, 900mm, 1200mm, 1350mm, 1500mm and 1800mm. Bespoke lintels are available to order.

How do you calculate a concrete lintel?

How To Calculate Steel Quantity Of Lintel Beam – Bar Bending…

  1. Length of one bar = 1.2+ (2 x 0.150) – 0.025 =1.475m.
  2. Length of 5 bars = 1.425 x 5 = 7.125m.
  3. Weight of steel for 10 mm bar = D²L/162 = 10² x 7.125/162 = 4.398 kg.
  4. Total length of stirrups = 0.632 x 11nos = 6.952m.

What’s the biggest concrete lintel you can get?

Use a lintel self-weight of 61 lb/ft (0.89 kN/m) and weight of 77.9 lb/ft² (3.73 kPa) for the bond beam at the top of the wall over the lintel (ref. 4). Check for arching action: The effective span length, L = 96 + 5.88 = 101.9 in. (2588 mm).

How are precast concrete lintels designed for strength?

Precast concrete lintels are designed using the strength design provisions of Building Code Requirements for Structural Concrete, ACI 318-99 (ref. 2). In strength design, service loads are increased to account for variations in anticipated loads, becoming factored loads.

What size lintels are available with a projecting keystone?

Finished on front face and soffit with the added feature of a projecting integral keystone, these lintels are available in 4 cross-section sizes with the keystone projecting as shown.

What are the building code requirements for a lintel?

LINTEL DESIGN Precast concrete lintels are designed using the strength design provisions of Building Code Requirements for Structural Concrete, ACI 318-99 (ref. 2). In strength design, service loads are increased to account for variations in anticipated loads, becoming factored loads. The lintel is then sized to provide sufficient design strength.